BOMB CALORIMETER Semi-Automatic Digital (With Microprocessor Controller)
INTRODUCTION
- For determination of heat combustion of organic matter and calorific value and sulphur content of coal, solid and liquid fuels.
- The Bomb has a capacity of 300ml approximately.
- The bomb is provided with a high-pressure Schrader valve, which opens and allows filling of bomb, by oxygen because of oxygen pressure from the cylinder.
- Each bomb is tested as per the requirement of Institute of petroleum (IP 12/63T).
- Supplied with Bomb Calorimeter Vessel with Bomb Support, Water Jacket, and Combined Lid for Calorimeter Vessel.
- Supplied with water Jacket, Stirrer, Connecting leads, connecting tube to connect bomb and pressure gauge.
- Connecting tube with fine adjustment valve to connect pressure gauge and oxygen cylinder.
- With pressure gauge on stand, spanner for oxygen tube connection, ignition wire (2 meters) Nichrome.
- With Cotton Reel, stand for Bomb Lid, Hook for lifting Bomb, Stainless Steel Crucible.
- With Gelatine Capsules, Gas Release Valve, Jacket Thermometer.
- With Bomb Firing Unit and Pellet Press.
DIGITAL FEATURES
- State of art technology microcontroller based for measurement of temperature to calculate the calorific value experiments in bomb calorimeter.
- JUMBO size 16 x 2 characters LCD display with backlight.
- Temperature scanning resolution of 0.01⁰C.
- Timer control through RTC(Real Time Clock) which makes it highly accurate.
- Thermal printer interface for printing the final result.
- Thermal printer Printout Report Format for SAMPLE TEST
- TYPE OF TEST :- SAMPLE TEST
- MAX.TEMPERATURE RISE
- MASS OF TABLET
- WATER EQUIVALENT
- FINAL CALCULATED CALORIFIC VALUE
- DATE & TIME OF TEST
- Thermal printer Printout Report Format for Water Equivalent Test
- TYPE OF TEST :- WATER EQUIVALENT TEST
- MAX.TEMPERATURE RISE
- MASS OF TABLET
- BENZOIC ACID CALORIFIC VALUE
- FINAL CALCULATED WATER EQUIVALENT
- DATE & TIME OF TEST
- 16 soft-touch Keypad for Menu driven settings of different parameters.
- Automatic detection of temperature rise & fall.
- Automatic measurement and mathematical calculation of the calorific value/Water Equivalent; which eliminates the requirement of operator to be continuously present to note the maximum temperature rise & to do the calculations manually.
- Weight of tablet settable through keypad by user.
- Water equivalent settable through keypad by user.
- Automatic calculation for Sample Test or Water Equivalent Test from maximum temperature rise value.
- Full test report printout with date and time & company name.
- Automatic alarm on Firing as well as after the test completes.
- Sensor open detection.
- Fuse wire open detection.
- No paper or printer door open detection.
- User friendly system handling messages on LCD
- Type of test selectable
Technical Specifications & Ordering Informations |
||
Control & Display |
Capacity |
|
Semi-Automatic Digital (�Processor Controller) |
300 ml |
Optional Accesorry:
- Oxygen Cylinder